Pneumatic hot melt systems are run by air in both the pump and the applicator guns. One of the most important ways to ensure the longest run time out of any pneumatic system is to make sure that the air is clean and dry. That can be easier said than done. Most all packaging facilities have oil, water, or debris in their air. That is just the way it is. Some factories will install air cleaning systems and then add lubricators to lines to ensure that other equipment that requires oil runs smoothly. But even with the most expensive and elaborate air filtration system, there will always be some type of substance that gets by and can lead to issues in the pneumatic pumps of hot melt units. The simplest solution is to install an oil removal filter regulator to the air line running to the pump.
Oily air is our most commonly found issue inside facilities that have pumps stop up. The reason is because the shifters are manufactured with very specific tolerance clearance between the shifter spool and sleeve. This design is a necessity in order to get the pump to shift. Too much clearance and the air will just blow by the spool, never building up enough air pressure to pump. Too little clearance and the shifter will jam. That being said, if you have oily air or dirty air being run through the shifter, over time, that will cause a film to build up inside the shifter and cause a jam. Depending on the amount of oil or dirt in your air, and the number of hours the systems is run for, will determine how long this will take to happen. However, if you feel like your facility air is questionable, we suggest that you use the oil-removal filter regulator to prevent any shifter stop ups.
Another pump issue that can be caused by dirty or oily air is that it can get into the air motor and damage the rulon seals. The seals need to be tight to snuggly move up and down the air motor and if they get damaged by oil or dirt, that can lead to your pump not efficiently pumping. These seals can be replaced over time and should be checked every 2,000 hours.
Universal Systems offers pump rebuild kits for the seals, as well as sells the shifter valves in case you ever run into a pump issue caused by dirty, oily air. For more information on our pump rebuilding services, or for any technical support you might need, please call (561) 272-5542 or email sales@ussefl.com.