There are several reasons why a melter’s pump might stop working. The most common reasons are clogging of the ball and seat from foreign matter such as carton dust, and the actuator clogging due to dirty or oily air. No matter what the reason, if your pump stops pumping it needs to be replaced. Obviously, it much more cost effective to change out a pump then to replace the entire unit. However, it is not always easy to switch out a pump, especially if you are new to the line. Below are a few tips to help ease you through the process.
- Make sure the circuit breaker on the front of the unit is set to OFF once the applicator has reached normal application temperature.
- Shut OFF the input air to the pump.
- Set the pump regulator to zero and trigger all guns to relieve system pressure.
- When removing the old pump, rotate it slightly to break the suction and then pull it straight up and out.
- When installing the new pump, make sure to torque the screws 15-16 ft-lbs.
- Connect the pump electrical plug to tank receptacle and turn tank back on.
- Once the tank board reads that the tank has reached set temperature, wait 15 minutes. This will allow the glue around the pump hydraulics to get to temperature.
- After waiting 15 minutes, reinstall the air regulator and connect the airline and activate air.
If you have any further technical questions and want to speak with a technical sales rep, please call (561) 272-5442 or email sales@ussefl.com.