The best way to keep your packaging line up and running as efficiently as possible is to do preventative maintenance. Here at Universal Systems SE, we have advocated for regular packaging line maintenance, including all of your glue melter equipment and components. However, it is not only important to know when to do maintenance, it is also important to know how to do that maintenance. There are more mistakes made in the switching out of glue equipment and components than you may think. Whether you are changing out a filter or switching a pump, there are steps to take in order to ensure a smooth transition, with the least amount of downtime. Here are a few tips on switching some of our ProBilt hot melt equipment products.

Tank Filters

First and foremost, it is important to know the model of your tank. Even though that sounds like standard knowledge, there are many tanks that look similar but have different tank capacities, pump types and filters. Once you know the tank model, you can look up if you need to replace the entire tank filter or if you can replace just the screen. On USSE’s ProBilt tanks, for example, you have the option to change only the tank screen. This allows you to save some money long term, while still maintaining your tank. It is recommended that you make the change while the tank is in setback and to wear Kevlar gloves so that you don’t burn yourself. The tank filter is located on the side of the tank. It can be removed with a flat head screw driver. Once the complete filter assembly is removed, there is a long screw that secures the screen to the assembly. Simply remove that screw, switch the screen, and replace the filter assembly. If you are changing out the tank screen, make sure that you do not damage the filter bung or o-rings when making the switch. Also, be careful, the glue inside the filter is HOT.

In-line Gun Filters

These are the easiest of filters on your glue line to change out. In most cases, the filters can be reordered in packs of 5. Locate where the filter is on the filter assembly body and use a wrench to loosen and remove. Kevlar gloves should be worn, as the outside of the filter will be hot and there will be glue on the filter you are removing. Simply put the new filter in place and tighten.

Modules

Usually modules are switched out because they are dripping or leaking. This is typically caused by either char or end of life of seat and piston. Switching out a module is fairly simple. Before taking off the old module and replacing with the new, make sure that the system is not running. Each replacement module comes with 2 o-rings and 2 screws. Place the o-rings on the back of the module and secure it on the gun applicator with the new screws.

If you are running an H200, zero cavity or reduced cavity module, there are rebuild kits available.

Pumps

Switching out a glue pump is the least common practice on a packaging line. However, this is also simpler than you would think. Most technicians think that in order to change out a pump, you need to turn the tank off and let the glue cool. That is not always the case. If you are running a ProBilt tank and have an experience technician, he can switch out the pump while the system is still on. First, make sure you are wearing Kevlar gloves because the system will be hot. Turn off the air running to the system, this will limit any injuries. Remove the 3 bolts holding in the pump, use needle-nose pliers and do this carefully. Put the old pump on a large piece of cardboard where the glue can drain, cool and harden. Carefully put the new pump in, secure it with the 3 bolts and turn back on the air.

For any other questions about tank maintenance, please contact one of Universal Systems’ experienced technicians at (561) 272-5442 or email tech@ussefl.com