Spring Cleaning for Your Hot Melt Systems

It’s that time of year again, when the days are longer and everyone is motivated to do some Spring Cleaning. That should also apply to your hot melt equipment. Like most machinery, your hot melt tanks, hoses, guns, filters and nozzles need regular preventative maintenance and cleaning. Below is the maintenance recommendation schedule that Universal Systems SE provides to all of its customers regarding our ProBilt line of products.

ProBilt Melters

  • Replace tank filter every 500 hours or 3 months, whichever comes first
  • Clean tank with Purge Plus every 1,000 hours or 3 months, whichever comes first

                 *stock 2 – 3 tank filters per tank and 1 Purge Plus cleaner

ProBilt Pumps

  • Clean and Flush Pump every 2,500 hours utilizing Pump Service Kit B100-900
  • Replace Pump every 5,000 hours or until Pump stops pumping

*stock at least 1 pump to reduce any potential down time

ProBilt Hose

  • Flush out hoses when cleaning tank with Purge Plus every 1,000 hours

                 *make sure to disconnect hoses from guns when flushing with Purge Plus

                *stock at least 1 hose per length needed to reduce any potential down time

In-Line Filters

  • Replace every 150 hours

*stock 5 spare filters for each filter body

Gun Applicator

  • Only replace when it stops functioning –either the heater or RTD

*stock 1 spare gun applicator per line

Module

  • Replace module every 1,000 hours or every 6 months, whichever comes first

                *stock 2 – 6 modules depending on how many modules are on each gun being used

Nozzles

  • Replace nozzles every 120 hours or when they clog

*stock a minimum of 6 nozzles per line

                *If you clean nozzles, we recommend cleaning them with kit # 1658 every 100 hours or when they clog

 

To keep your stock up to date please give us a call at (561) 272-5442. A USSE sales rep will quote you pricing and lead time on anything you need.

Read More

How to Effectively Clean Your Melter

Keeping your hot melt adhesive system clean may not be on the top of your priority list. However, take a look at your melter now, it is probably bronzed and blackened with old melted glue and char in the glue reservoir. That is what travels through your application system and onto your boxes. That is also what is potentially causing clogging issues and why you are replacing so many nozzles. Even though your melter looks like this now, it is possible to clean it and positively impact the longevity of your system. We recommend that you clean your system at least once every quarter. If you are running 24-hour shifts, 7 days a week, then you might want to schedule cleaning once a month.

Universal Systems SE sells a product called Purge Plus™ that, when used properly, will clean almost any melter. The directions for use are simple:

  • Drain all hot melt from tank reservoir
  • Fill reservoir with Purge Plus™
  • Heat Purge Plus to 350°F – 375°F for approximately 45 minutes
  • Open tank drain valve and remove tank filter assembly
  • Slowly start pump and run Purge Plus™ through the tank manifold and into a meal container until reservoir is empty
  • Stop pump, replace filter assembly and close drain valve
  • Carefully wipe any remaining contaminants from tank reservoir
  • Add new hot melt and recirculate through system
  • Drain one cup from each hose

In addition to cleaning the tank reservoir and heated hot melt hoses, if you are running a ProBilt™ series melter, the exterior is manufactured out of 316 grade stainless steel. So, any stainless steel cleaner will shine the exterior of the tank.

For any additional questions about Purge Plus or how to properly clean your tank and hoses, please call a Universal Systems service technician at (561) 272-5442 or email tech@ussefl.com.

Read More

Starting Back Up After a Pandemic

This is most definitely a new reality that we are all facing. Never before have so many companies had to shut down several, if not all, of their packaging lines because of a global pandemic. However, it was a scary and necessary measure taken to prevent further outbreaks of COVID-19. Now, as we slowly start to reopen as a nation, so does our packaging facilities. State by state, Governors are rolling out the reopening phases that each company, both essential and non-essential must follow.

With the reopening happening, that may mean you are going to run into a few speed bumps. As we all know, machines that typically run seven days a week, don’t like being shut down for three months. Especially if they are not shut down and cleaned out properly before they sat around idle. So, when you switch the power button back to “ON”, everything might not turn green.

In an effort to help with troubleshooting, we have put together a quick list of potential fixes.

1. CLEAN YOUR TANK. We cannot stress this enough. Even if your team drained the glue in the tank reservoir before shut down, there will still be old residue that will impact your restart. Cleaning your tank is fairly simple. First, make sure to detach all guns from the hoses before running the cleaner through. Utilizing our Purge Plus cleaner, fill the tank reservoir and heat. Place the end of the hose inside a bucket and flush the cleaner through the tank and out through the hose.
2. CHANGE ALL FILTERS. This includes both the tank filter and in-line gun filter. Starting with new fresh filters is the smart way to go.
3. NOZZLES MIGHT GET CLOGGED UPON INITIAL RESTART. Nozzles have small orifices that dispense the glue onto packages. If there is any left-over char in the tank from restart, the nozzles could get clogged up first. Try switching the nozzle to see if that fixes the issue.
4. REBUILD KITS. There are a few items that can be rebuilt on your adhesive melter system. For example, your pump. If you think that your seals have dried up from sitting idle through the down time, and you have a skilled mechanic trained to work on the equipment, try ordering a rebuild kit. This will save you money on purchasing a new pump.

If you experience any other issues during your restart, please call us directly at (561) 272-5442 and a technician will walk you through troubleshooting any issue. Stay Safe!

Read More

Keep Your Melter Clean

Keeping your hot melt adhesive system clean may seem like an impossible task. Take a look at your melter now, it is probably bronzed and blackened with old melted glue. Well guess what…that is what travels through your application system and onto your boxes. Also, do you see all of the little bits of blackened glue? That is called char, and it is a big problem for your equipment. Even though your melter looks like this now, it is possible to keep it clean “ish”. Now, this melter runs in a packaging line, most likely 8 – 12 hours per day, every day, so there is no way that tit is going to stay pristine or even look clean after its first use. However, there are a few tricks of the trade to keep your melter looking good and running even better for decades to come.

Universal Systems SE sells a product called Purge Plus™ that, when used properly, will clean almost any melter. The directions for use are simple:

  • Drain all hot melt from tank reservoir
  • Fill reservoir with Purge Plus™
  • Heat Purge Plus to 350°F – 375°F for approximately 45 minutes
  • Open tank drain valve and remove tank filter assembly
  • Slowly start pump and run Purge Plus™ through the tank manifold and into a meal container until reservoir is empty
  • Stop pump, replace filter assembly and close drain valve
  • Carefully wipe any remaining contaminants from tank reservoir
  • Add new hot melt and recirculate through system
  • Drain one cup from each hose

In addition to cleaning the tank reservoir and heated hot melt hoses, if you are running a ProBilt™ series melter, the exterior is manufactured out of 316 grade stainless steel. So, any stainless steel cleaner will shine the exterior of the tank.

For any additional questions about Purge Plus or how to properly clean your tank and hoses, please call a Universal Systems service technician at (561) 272-5442 or email tech@ussefl.com.

Read More

When Consumers Can’t Open their Boxes

Have you ever purchased a case of soda or carton of coffee cups and can’t get the box open? Of course, we all have. In the packaging industry, especially for hot melt machine manufacturers, that is a red flag. Whenever we get a box that has too much hot glue on it means that the packaging line is not set up properly or not being cleaned regularly.

If you are wondering why too much glue means that the line is not set up properly or not being cleaned regularly it is because one of two issues is occurring (or sometimes even both). The first issue is most likely that the line operators and/or maintenance managers are not cleaning the tank regularly and the lines are clogging up with char, which will subsequently clog nozzles. Instead of cleaning the tanks and hoses, and replacing the tank filter and in-line gun filters, most operations just buy bigger nozzles. If the diameter of the nozzle orifice is larger, then it will allow through more bits of char and not clog up as easily. Unfortunately, this is not a long-term solution. Putting down more hot glue will drive up the amount that facilities spend on adhesive pellets, and ultimately the annoyance will trickle down to the consumer when they can’t get their box open. The solution is simple…utilize Purge Plus to clean your tank every 1,000 hours. For some facilities that could mean cleaning every quarter and for others that could be twice a year, it all depends on the facility. In addition to cleaning the tank and hoses with Purge Plus, make sure that the tank filters are changed every 500 hours. The in-line gun filters should be changed every 150 hours to ensure that no char travels into the gun applicator, through the module and nozzle and onto the box.

The second issue that could cause too much glue on boxes, is that the line was not set up correctly from initial purchase. A lot of cartoners have standard hoses, guns, modules and nozzles that will work for most case packers, but not for all. Make sure to take into consideration the temperature of your packaging facility (which can impact the adhesion and viscosity of the glue as it travels through the application process), the distance that the guns are to the box upon application, and the surface area of the box you are covering. The longer the bead of glue you place, the less likely you are to need a larger diameter nozzle. The shorter the range you are covering, you might need more glue to make sure that maximum adhesion occurs, which means you need a larger diameter nozzle.

If you think you are putting down too much glue on your packaging line and need help, call one of Universal Systems’ technicians at (561) 272-5442. We have the most knowledgeable technicians in the business that can help you with almost any question.

Read More

Not All Glue Melts Well Together

One of the most common customer service calls we receive has to do with adhesives that get mixed together and then create a mess inside the melter tank. It is important for any packaging line operator to understand that not all glue is made equal, which means they might not mix well together. Especially when operating at high heat with high demand.

Know Your Adhesive

There are two main types of adhesives that you could be using in your tank: ethylene-vinyl acetate (EVA) and polyolefin. EVA is a copolymer adhesive, most commonly used in the paper, packaging, and assembly industries, as they bond to a variety of cellulosic materials and have a wide range of formulation. Polyolefin is used mostly at low application temperatures and works best in spray or film form. The best thing to do is keep the adhesive information so that you do not accidentally order the wrong type of adhesive and mix them together. When EVA and PVA are mixed together and heated, they create a thick gelatin formulation that will destroy your melter pot. This is not something that can be cleaned out, even with the strongest of cleaners.

Clean & Purge Your Tank

It is imperative, whenever starting a new batch of adhesive to thoroughly purge and clean your tank, hoses and guns. Removing all remanence of previous adhesive build up. This will prevent any clogs or char from filtering through your adhesive system and causing any unnecessary adhesive mixing. Universal Systems offers a cleaner called Purge Plus that, when heated to the correct temperature within your tank, will remove all of the old adhesive and char.

For more information on Universal Systems SE or our Purge Plus cleaner, please contact us at (800) 848-5018 or email us at sales@ussefl.com.

Read More